Building type · Data center

Data center buildings

Steel shells for edge and enterprise data centres: a sealed, insulated envelope, a roof designed to carry cable trays, ducts and fire lines, and a programme fast enough to keep pace with IT demand.

Scroll to see how we build it

Design it yourself

Start from a ready size

Open any of these in our free 3D designer, change the size, roof, doors and colours, and get a design sheet with a budget quotation in minutes.

Overview

Data center buildings in steel

A data centre shell has a simple brief and strict details: keep the weather out, keep the heat and dust out, and carry a dense web of services. We build data centre and edge data centre shells on a pre-engineered steel frame with insulated panels on the roof and walls and no skylights or ventilators, so the envelope stays sealed.

The roof is designed for the services that hang from it: cable trays, chilled-water and fire lines, ducts and containment, with a collateral load of at least 0.5 kN/m². Equipment doors are framed for the racks, UPS and switchgear that need to come in.

Steel is quick to erect, so the shell is ready for the fit-out teams sooner, and further halls can be added along the same grid as capacity grows.

Why pre-engineered

Why build your data center in PEB

What a pre-engineered steel frame gives a data center owner.

01 / Envelope

Sealed shell

Insulated panels and sealed joints keep heat, dust and water out.

02 / Services

Roof built for services

Cable trays, pipes and ducts are designed into the roof load.

03 / Speed

Fast to fit-out

Steel shells close in quickly so the IT fit-out starts earlier.

04 / Scale

Add halls

Extend along the grid as racks and power grow.

05 / Layout

Free white space

Clear spans leave the hall free for rack rows and containment.

06 / Budget

Efficient shell

A light steel shell puts more of the budget into the IT and cooling.

Engineering

What we design for

Services loadAt least 0.5 kN/m² on the roof for trays, pipes and ducts; more when your MEP design needs it.
Sealed envelopeInsulated panels, no skylights or turbo vents, sealed trims.
Equipment accessDoors and a loading canopy sized for racks, UPS and switchgear.
Plant loadsChillers, generators and tanks on the ground or a designed platform; loads from your MEP consultant.

How it works

From 3D design to handover

The building in the background goes up in the same order as you scroll.

01

Design in 3D

Set the size, roof, openings and colours in our designer and send it for a quotation.

02

Engineering

Our engineers design every member to IS 800 and IS 875 for your site and issue the drawings.

03

Fabrication

Columns, rafters and purlins made to measure in the plant, painted and marked.

04

Erection

Our crews erect the frames, bracing and sheeting bay by bay.

05

Handover

Final checks, quality records and the keys to your data center.

FAQ

Data center questions

Short answers to what owners ask. For your exact building, design it in 3D or call us.

Yes. Many edge and enterprise data centres use a steel shell with insulated panels. The shell is quick to build and the clear span suits rack rows and containment.

Our designer uses at least 0.5 kN/m² of collateral load for cable trays, pipes and ducts. Heavier services or roof plant are added from your MEP design.

A data hall needs a sealed, controlled envelope. Daylight and natural ventilation would let in heat, dust and moisture.

No. We build the shell and coordinate openings, supports and levels with your MEP and IT contractors.

Yes. Start from the data center preset in our 3D designer, set the size and doors, and download a design sheet and budget.

Insights

Guides before you build

Other buildings

More we build

Free 3D designer

See your data center first

Design it on screen, download the design sheet, and get a budget quotation from our engineers. No drawings needed to start.

Design it in 3D Talk to an engineer Call the office79747 10028